10 GKND-SVX01B-EN
Unit Dimensions and Weights
Table 1. Performance and specification data: Separated Combustion Blower Unit Heater
Unit Size 100 125 150 175 200 225 250 300 350 400
PERFORMANCE DATA
(a)
Input BTU/Hr 100,000 125,000 150,000 175,000 200,000 225,000 250,000 300,000 350,000 400,000
(kW) (29.3) (36.6) (43.9) (51.2) (58.6) (65.9) (73.2) (87.8) (102.5) (117.1)
Output BTU/Hr 80,000 100,000 120,000 140,000 160,000 180,000 200,000 240,000 280,000 320,000
(kW) (23.4) (29.3) (35.1) (41.0) (46.9) (52.7) (58.6) (70.3) (82.0) (93.7)
Thermal Efficiency %80808080808080808080
Free Air Delivery CFM cfm 1,200 1,575 1,975 2,300 2,400 2,600 2,850 3,950 4,600 4,800
(m
3
/s) (0.566) (0.743) (0.932) (1.086) (1.133) (1.227) (1.345) (1.864) (2.171) (2.266)
Air Temperature Rise °F 62 59 56 56 62 64 65 56 56 62
(°C) (34) (33) (31) (31) (34) (36) (36) (31) (31) (34)
Outlet Velocity fpm 880 950 1030 1045 965 935 930 1080 1090 1000
(m/s) (4.47) (4.83) (5.23) (5.31) (4.90) (4.75) (4.72) (5.49) (5.54) (5.08)
Full Load Amps at 115V 8.3 9.8 10.6 10.6 15.2 15.2 15.2 15.2 18.6 18.6
MOTOR DATA
Motor hp 1/4 1/3 1/2 1/2 3/4 3/4 3/4 3/4 1 1
(kW) (0.19) (0.25) (0.37) (0.37) (0.56) (0.56) (0.56) (0.56) (0.75) (0.75)
Type SPHSPHSPHSPHSPHSPHSPHSPHcap.startcap.start
RPM 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725
Amps @ 115V 5.1 6.6 7.4 7.4 12.0 12.0 12.0 12.0 15.4 15.4
DIMENSIONAL DATA
A” Height to Top of Unit in. 31-1/4 31-1/4 36-1/4 36-1/4 36-1/4 36-1/4 36-1/4 36-1/4 36-1/4 36-1/4
(mm) (794) (794) (921) (921) (921) (921) (921) (921) (921) (921)
“B” Height to Top of Hanger in. 34-1/16 34-1/16 39-1/16 39-1/16 39-1/16 39-1/16 39-1/16 39-1/16 39-1/16 39-1/16
(mm) (865) (865) (992) (992) (992) (992) (992) (992) (992) (992)
“C” Hanging Distance Width in. 14-3/4 17-1/2 17-1/2 20-1/4 23 25-3/4 28-1/2 34 39-1/2 45
(mm) (375) (444) (444) (514) (584) (654) (724) (864) (1003) (1143)
“D” Discharge Opening Width in. 15-3/8 18-1/8 18-1/8 20-7/8 23-5/8 26-3/8 29-1/8 34-5/8 40-1/8 45-5/8
(mm) (391) (460) (460) (530) (600) (670) (740) (879) (1019) (1159)
“E” Width of Unit in. 17-7/8 20-5/8 20-5/8 23-3/8 26-1/8 28-7/8 31-5/8 37-1/8 42-5/8 48-1/8
(mm) (454) (524) (524) (594) (664) (733) (803) (943) (1083) (1222)
“F” to Centerline of Flue in. 5-7/8 7-1/4 7-1/4 8-5/8 10 11-1/4 12-3/4 15-1/2 18-1/4 21
(mm) (149) (184) (184) (219) (254) (286) (324) (394) (464) (533)
G Hanging Distance Depth in.18-1/218-1/218-1/220202323232323
(mm) (470) (470) (470) (508) (508) (584) (584) (584) (584) (584)
“H” Depth to Rear of Housing in. 42-3/4 44-3/8 44-3/8 47-3/16 47-3/16 50-7/8 48 50-7/8 50-7/8 51
(mm) (1086) (1127) (1127) (1199) (1199) (1292) (1219) (1292) (1292) (1295)
Flue Size Dia. in.**4444555666
(mm) (102) (102) (102) (102) (127) (127) (127) (152) (152) (152)
Air Inlet Size in.4444555666
(mm) (102) (102) (102) (102) (127) (127) (127) (152) (152) (152)
Blower Size in. 9 10 10 12 12 12 12 (2) 10 (2) 12 (2) 12
Gas Inlet-Natural Gas in. 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4
Gas Inlet-LP Gas in. 1/2 1/2 1/2 1/2 1/2
1/2 or 3/4
Approx. Shipping Wt. lb 298 330 362 394 426 458 490 558 618 678
(kg) (135) (150) (164) (179) (193) (208) (222) (253) (280) (308)
Notes:
1. For installations in Canada, any references to deration at altitudes in excess of 2000 ft. (610 m) are to be ignored. At altitudes of 2000 to 4500 ft.
(610 to 1372 m), the unit must be derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification.
2. Legend: SPH = SPLIT PHASE, CAP. START = CAPACITOR START
(a) Ratings shown are for unit installations at elevations between 0 and 2000 ft. (610 m). For unit installations in USA above 2000 ft. (610 m), the unit
input must be derated 4% for each 1000 ft. (305 m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the
National Gas Code, ANSI Standard Z223.1 (N.F.P.A. No. 54).